Homepage About Bennett Scientific Ltd Email: sales@bennett-scientific.com







The Clifton range of Fan Assisted Drying Ovens

MODEL NE9-15S NE9-32S NE9-56S NE9-112S NE9-240S NE9-400S NE9-750S
Int.Dim's mm 320w
180d
240h
400w
250d
320h
400w
400d
360h
400w
450d
620h
600w
510d
800h
800w
510d
1040h
1040w
600d
1200h
Ext.Dim's mm 520w
390d
600h
600w
460d
680h
600w
605d
720h
600w
660d
980h
800w
720d
1160h
1000w
720d
1470h
1240w
810d
1625h
Flucation@150C ± 0.4C 0.4C 0.4C 0.4C 0.4C 0.8C 0.8C
Variation@150C ± 1.8C 1.8C 1.8C 1.8C 1.8C 2.5C 2.5C
Power Consumption 1050W 1100W 2150W 2150W 3200W 4250W 5250W
Shelves supplied 1 1 2 2 3 3 5
Max No of Shelves 3 3 5 8 10 14 16
List price 1250.00 1350.00 1450.00 2000.00 2500.00 4500.00 6000.00
Our Offer Price 1125.00 1215.00 1305.00 1800.00 2250.00 4050.00 5400.00
*All prices exclude VAT, Packing and delivery*

The Clifton NE9 range of Fan Assisted Drying Ovens feature precision
time and temperature control with programming options from ambient +5C to 300C.
They allow for heating cycles to produce a controlled environment above ambient.

Microprocessor control with auto diagnostics, digital LCD display to 0.1C resolution, three program memory with event log of actual temperature and time data.

Featuring wipe clean touch pad controls illuminated LCD display for viewing wide range of settings, programs, temperature and time values.

The high grade 304 spec stainless steel chamber is sealed shut with a solid door. Other door options available include a window in the door or an internal glass door allowing the observation the chamber with no temperature disturbance.

Details:

  • Range: ambient +5C to 300C.
  • Microprocessor control, dual pt100 temperature probes.
  • Temperature and time programmable in two ways:
    • Six segment temperature-time profile with delay start, heating up, hold at set point, each with timers from 1 minute to 99 hours.
    • Continuous mode at set point with either delay start , or timed up to 999 hours.
  • Auto diagnostic system.
  • Digital illuminated LCD to 0.1C resolution.
  • Calibration Certificate @ 105C.
  • Date and time setting, program can start unsupervised.
  • Audible alarm and display, setting 0.5C to 5.0C about set point.
  • Fast temperature rise to attain set point or normal with no overshoot.
  • Three program memory, re-called for use.
  • Event log and program review temperature and time records.
  • Average minimum and maximum temperature values recorded for each segment of the program for reference and validation.
  • Manual Air-flap control, adjustable.
  • Forced air circulation with Fan speed regulation from 10 to 100%.
  • 304 stainless steel interior for long working life and easy cleaning.
  • Hard wearing powder painted exterior.
  • Voltage: 230V
  • 2 year warranty
  • Over-temperature protection:
    • Cass 1, thermal cut out 310C and separate element overheat protection.
    • Class 2, experiment/sample protection, adjustable setting above set point, heating switched off, audible and visual indication.
    • Accessory options Class 3, temperature protection, self resetting cut outs.
    • Temperature sensor fail alarm.
    • Power failure control with auto resume.
  • Safety Class: 1 + 2 fitted, options for 3+
Additional Notes :
  • Before ordering please check the room or building access where this unit will be installed and electrical power requirements.
  • Sensitivity measurements based on temperature readings on shelf in centre of the chamber.
  • Uniformity measured in vertical axis in the chamber using Wired Shelves.
  • Working capacity of chamber can be smaller.
  • With the solid door design a viewing window can be specified.
  • Ovens up to 115 litres are stackable.
  • Do not place in direct sunlight and allow a 100mm air gap away from wall at rear. Ensure there is a minimum 300mm air gap from top of the unit to ceiling.
  • When no programs are active, the display shows current time and temperature inside chamber. When running a program the display shows program number, temperature inside chamber and status symbol showing the status of heating.

A range of factory fit options are as follows (please ask for prices):
  • Viewing window
  • Wire Shelf
  • Perforated SS Shelf
  • Drawer unit
  • Castors
  • Class 3 Over-temperature protection
  • 3.1 HEPA air filter in the air inlet
  • Open door counter, counts events
  • whilst program is running
  • Additional PT100 Temperature sensor built in for independent measurements
  • Audible door alarm
  • Factory Calibration @ 37C
  • Factory Calibration @ 37C
  • Factory Calibration, 9 Point check.
  • Qualification procedure
  • Converter from RS232 to RS422
  • Converter from RS232 to RS485

All prices are in pounds sterling and exclude VAT, packing and carriage.
Prices and specifications are subject to change. Please check when you order.
Prices last updated 1st January 2021.

See also:
Clifton Fan Assist Ovens
Clifton Fan Assist Incubators
Clifton Waterbaths
Clifton Wet & Dry Block Heaters
Clifton Metalware





Last modified 01/01/2021